NIS-Elements Preferences

Adjusting Program Preferences

  1. Run the Edit > Options command. The Options dialog window appears.

  2. Select a tab which contains requested options. Options are sorted into several groups:

    General

    Options concerning basic image operations. See General.

    Appearance

    Options concerning the graphical user interface. See Appearance Options.

    Macro

    Configures key shortcuts to macros and sets macros to run automatically on startup See Macro Preferences.

    Measurement

    See Measurement Options for more information.

    Data export

    See Data Export Options for more information.

    User rights

    See User Rights for more information.

    Layout Manager

    See Layout Manager for more information.

  3. Make any changes you need in preferences and use the following buttons to manage them:

    Defaults for this Page

    Restores default settings of the currently displayed options tab.

    OK

    Confirms and saves changes made to the preferences. The dialog window is closed afterwards.

    Cancel

    Cancels all changes made to the preferences. The dialog window is closed afterwards.

    Apply

    Applies changes made in preferences but keeps the Options dialog window open. You can apply changes individually on each tab.

    Help

    Displays the relevant help page.

General

Documents and History
Use fix path for images

The defined directory is always used when using the File > Open or File > Save As command.

Allow only one opened document

If checked, only one document at a time can be opened.

Limit number of opened images

Limit the number of images, which can be opened at one time. The maximum is 128 opened images.

Capture always creates a new document

If checked, every acquisition creates a new image.

Use last LUTs on image open

When a new image is opened, this option turns the look up tables automatically on, and copies the settings from the current or the last opened image. Some image formats (JP2, ND2) can contain the LUTs settings. If such image is opened, the saved LUTs are loaded instead of the most recently used.

Use AutoLUTs on image open for images without LUTs information

This option keeps the AutoLUTs feature of the File > Open window always ON, and it applies AutoLUTs to the image after opening. This option is ignored if LUTs settings are saved in the image, or if the Use last LUTs on image open option is applied.

Show mapping dialog in organizer after drag and drop

Displays the Mapping window every time an image is inserted to a database table. It enables you to check/modify mapping of the image info values to the database table fields.

Open new ND views to new window

Displays each newly generated ND view in a separate window.

Enable authentication

Authentication verifies each image frame and detects changes in image data made after acquisition. Modifications are indicated in the Image Properties dialog. See File > Image Properties.

Note

Authentication works with images acquired by the Capture button, the ND Acquisition dialog(s).

Show image info window on save

Displays the File > Image Properties window every time an image is saved via the Save As command.

Detect sequence on image open

When you select to open an image that is a part of image sequence such as 001.JP2, 002.JP2..., it is recognized automatically and you are offered to convert it to an ND2 file.

Show binary layers' contours

Check this item to display contours of binary layers.

Use zero based time scale for ND documents

Select this option to ensure that the first frame of a time sequence will always start at 0.0s.

State of saturation indicator after start

Select what to do with the saturation indicator settings () after NIS-Elements is restarted. Turn it ON, OFF, or remember the last setting.

Rotation, Flips and Shifts
Apply to overlaid binary layer

If checked, in overlay mode both binary and color images are rotated, shifted and flipped.

Optical Configuration
Save changes to optical configuration automatically

Make changes to the current optical configuration without warning? If selected, some setting changes are written to the optical configuration immediately and the exclamation mark would not appear by the OC name. Select the settings to be changed without warning:

Exposure Only

Camera exposure time only.

All Camera Settings

All camera settings such as exposure, gain, resolution, etc.

All Brightness Settings

All Camera Settings plus selected settings of illumination-related devices such as laser power, light power, etc.

Select corresponding optical configuration when filter or nosepiece changed

Enabled if Unselect in the option below is chosen.

Allows NIS-Elements to automatically change the optical configuration based on the filter or nosepiece selected on the microscope.

When Optical Configuration setting changed
Keep Selected

The Opt. configuration name is marked by the * sign and the change is offered to be saved.

Unselect

Every change of Optical configuration setting results in its deselecting and switching to user settings.

Save all changes

All changes regarding the Opt. configuration settings are updated automatically according to the current state.

Temp

NIS-Elements uses the Temp directory for storing temporary data when there is not enough RAM available. You can redirect the system to use a directory on another hard disk, which may speed up the whole system.

Defaults for This Page

Restores the default setting for General Options.